CENTURION GATE MOTORS IN MIDRAND
We specialize in installations and repairs of Centurion gate motors in Midrand, Gauteng and surrounding arears
Centurion Residential Gate Motors
Centurion Industrial Gate Motors
Centurion Slidding Gate Motors
Centurion Swing Gate Motors
Request for Quotation
Centurion gate motors are another popular brand in the gate automation industry, known for their high-quality and innovative products. Centurion Systems, the company behind these motors, offers a variety of gate automation solutions tailored to different needs, including residential, commercial, and industrial applications.
Centurion GATE MOTOR Installation
We supply and install Centurion motor gate systems accordign to customer requirements. We do free site inspections and measurements to ensure we provide our customers with correct solution for their motor gate.
Centurion gate motor Repairs near you
We repair and mantain any type of Centurion gate motor. from faulty components, wiring, upgrades or general maintenance. We provide guaranteed service to bring your centurion motor gate back to its best performance.
Centurion gate motor prices
Centurion gate motor prices are affected by many factors such as the size of the gate, user and other operational requirements. to ensure you get the correct price for the motor, its recommended you provide us with with requirements. We arrange site meetings to do proper onsite inspections which is critical to ensure that we spec the correct motor.
Below are some indicative Centurion gate motor prices
Centurion D3 Smart Gate Motor Price
Experience the smart security you deserve, now within reach. The D3 SMART gate motor embodies the philosophy of simplicity being the pinnacle of sophistication. It combines sleek design and premium performance with intelligent features, making secure and reliable gate automation accessible to everyone.
D3 SMART is packed with advanced – yet intuitive and user-friendly – functionality to make your life easier. Effortlessly control your gate with the MyCentsys Remote smartphone app, receive advanced diagnostic feedback for ultimate peace of mind, and enjoy dependable battery-driven technology that stands up to power outages.
Installer-friendly, feature-rich, and budget-conscious, D3 SMART is the smarter choice for your home.
Here’s why you’ll love the D3 SMART:
- Fast and Secure: Open your gate in a flash, keeping unwanted visitors at bay
- Smart Control: Manage your gate with maximum convenience and flexibility with the user-friendly smartphone app
- Easy Installation: Saving installers time and effort with the industry-leading design
- Reliable Performance: Never miss a beat with dependable battery-driven technology
- Intelligent Features: Advanced alerts, notifications and reporting keep you informed and in control
- Peace of Mind: Enjoy outstanding security with the improved theft-resistant cage
- Convenient Commissioning and Operation: Effortless smartphone setup and single-action manual release
- Wireless, Effortless Safety: Compatible with Photon SMART Beams for a complete wireless experience
Centurion D5 Evo Gate Motor Price
The iconic D5-Evo, reimagined. The gate motor synonymous with reliability and performance just got smarter. Introducing the D5-Evo SMART, powered by award-winning technology and designed to enhance your security experience.
More than just an upgrade, it’s an evolution. The D5-Evo SMART retains the legendary strength and dependability of its predecessor, now enhanced with intelligent features that put you in complete control. Enjoy effortless smartphone control, advanced diagnostics for ultimate peace of mind, and dependable battery-driven technology that keeps you protected even during power outages.
Unleash the power of SMART:
- Seamless Control: Manage your gate with maximum convenience, control and flexibility with the user-friendly smartphone app
- Intelligent Insights: Advanced notifications, alarms, monitoring and reporting keep you informed and in control
- Uninterrupted Security and Convenience: Dependable battery-driven technology ensures seamless operation even during power outages
- Effortless Setup: Wireless configuration and smartphone control make installation a breeze
- Enhanced Security: The improved theft-resistant cage and advanced position control system offer unparalleled peace of mind
- Ultimate Versatility: Individually-configurable inputs and outputs allow for harmonious integration with your SMART ecosystem
The D5-Evo SMART is a statement. It’s a monument of innovation, a commitment to security, and an assurance of peace of mind. Experience the future of gate control, powered by the legacy of the D5-Evo.
Centurion D6 Smart Gate Motor Price
With unsurpassed convenience and control at your fingertips, you’ll love using the D6 SMART.
All the most innovative technological features
- Onboard multichannel NOVA receiver with 1500 button memory
- Wireless and effortless – easy setup and configuration from your smartphone
- 24V system capable of performing more operations and offering extended battery backup and power failure autonomy
- New and improved theft-resistant cage with a patented design offering outstanding security and peace of mind
- Vibration sensor that can be connected to a third party device to notify you in the event that the gate motor is being tampered with
- Intelligent battery charger with onboard diagnostics and SMART communication between the charger and the controller
- Improved position control system incorporating hall effect technology – highly resistant to interference
- Individually-configurable inputs and outputs
- Convenient and intuitive single-action manual release
Centurion D10 Smart Price
Suitable for gates with weight of upto 1000Kg
The legendary high-volume performer. The powerhouse of heavy-duty access control. The intelligent choice in commercial and industrial gate automation. Now with award-winning SMART technology.
Main features:
- Taking intelligence to the next level – a machine crafted for excellence and perfected through innovation
- Pushing the limits of technology to bring you the ultimate in strength, security and endurance – suitable for gates weighing up to 1t with 750 daily operations
- SMART hardware and SMART connectivity provide the best experience for installers
- Intelligent theft and break-in protection with an integral vibration sensor and patented theft-deterrent cage
- More space and dedicated accessory tray for complementary solutions such as GSM devices
- World-class reliability with a sealed gearbox and improved, more secure manual release mechanism
- Die-cast aluminium gearbox coupled with a high-torque DC motor built for pure power and performance
- Uncompromising security, uninterrupted convenience with 24V battery backup
- Instant access to advanced, in-app diagnostics and logs, monitoring system health in real time
- Accurate and safe position control incorporating reliable Hall Effect technology
- Improved wire routing
- SMART universal controller – compatible with all CENTURION SMART solutions
CENTURION GATE MOTOR SWING TYPE
Sleek, stylish, secure and strong: these are some of the words that describe the VANTAGE linear swing motor gate for domestic and industrial gates. VANTAGE gate automation comes standard with battery backup offers a quick and easy (not to mention good looking) installation. It is an exceptionally strong set of operators for gates up to 4m wide, per leaf (consult specifications for further details). Boasting tough-as-nails die-cast aluminium construction throughout, a grade 304 stainless steel wormshaft for the ultimate in reliability and durability and with sophisticated electronics for smooth, safe operation, VANTAGE gives you everything you need to swing the future your way.
Centurion VANTAGE specifications
- Exceptionally easy system setup via LCD user interface.
- Supports inward- and outward-opening gates without needing mechanical endstops.
- High push force.
- Full position control.
- Fast operating speed, with smooth acceleration and deceleration.
- Safe anti-crushing protection.
- Multiple operating features including Intruder-detection Alarm Modes (a world first).
- Onboard CENTURION code-hopping multichannel receiver with selective add and delete.
- Battery backup for uninterrupted operation during power failures.
CENTURION GATE MOTOR REPAIRS
Centurion gate motors are known for their reliability and durability. However, even the best gate motors can encounter problems over time. Understanding the common issues that can arise with Centurion gate motors is the first step towards efficient repairs.
GATE MOTOR Control Board
One of the most common issues is a faulty control board. The control board is the brain of the gate motor, responsible for receiving and interpreting signals from the remote control or keypad. If the control board malfunctions, it can lead to the gate motor not responding to commands or behaving erratically.
Another common problem is a worn-out gear. The gear is responsible for transferring power from the motor to the gate, enabling it to open and close smoothly. Over time, the gear can become worn or damaged, resulting in a gate motor that struggles to operate or makes grinding noises.
It’s essential to identify these common issues early on to prevent further damage and ensure a quick and efficient repair. In the next section, we’ll discuss the importance of regular maintenance for Centurion gate motors.
Importance of regular maintenance for Centurion motor gate
Regular maintenance is crucial for keeping your Centurion gate motor in optimal condition. By performing routine checks and maintenance tasks, you can identify and address potential issues before they escalate into more significant problems.
One of the most important aspects of regular maintenance is lubrication. Proper lubrication of the moving parts, such as the gears and chains, helps reduce friction and wear. It’s recommended to lubricate the gate motor at least twice a year or more frequently if the gate is exposed to harsh weather conditions.
Inspecting the gate motor’s components is another essential part of maintenance. Check for any signs of wear or damage, such as cracks in the control board or loose chains. Tighten any loose screws or bolts and replace any damaged parts promptly.
Regularly cleaning the gate motor is also important. Dust and debris can accumulate over time, affecting the motor’s performance. Use a soft cloth or brush to remove any dirt or grime from the motor’s exterior and ensure proper ventilation.
In addition to these maintenance tasks, it’s essential to test the gate motor regularly. Open and close the gate multiple times to ensure smooth operation and listen for any unusual noises. If you notice any issues during the testing, it’s recommended to troubleshoot and address them promptly.
By incorporating regular maintenance into your gate motor care routine, you can prolong its lifespan and avoid costly repairs. However, if a repair is needed, it’s essential to know how to troubleshoot the problem yourself before considering professional help. In the next section, we’ll provide step-by-step instructions for DIY troubleshooting of Centurion gate motor repairs.
DIY troubleshooting for Centurion gate motor repairs
Before jumping straight into hiring a professional for gate motor repairs, it’s worth attempting some DIY troubleshooting. Not only can this save you time and money, but it can also give you a sense of accomplishment in resolving the issue yourself.
The first step in troubleshooting is to check the power supply. Ensure that the gate motor is receiving power by testing the electrical outlet or circuit breaker. If there is no power, check for any tripped breakers or blown fuses and rectify the issue.
If the power supply is not the problem, the next step is to inspect the control board. Look for any visible signs of damage, such as burnt components or loose connections. If you find any issues, it may be necessary to replace the control board with a new one.
Next, examine the gear and chain. Check for any signs of wear or damage, such as missing teeth on the gear or a broken chain link. If you find any issues, you can replace the gear or chain yourself using the manufacturer’s instructions or seek professional assistance if needed.
In some cases, the problem may be related to the gate’s alignment. If the gate is misaligned, it can put excessive strain on the gate motor, leading to issues with operation. Adjusting the gate’s alignment may require loosening and repositioning the gate brackets or hinges.
If you’ve gone through these troubleshooting steps and still haven’t resolved the issue, it may be time to consider hiring a professional for Centurion gate motor repairs. In the next section, we’ll discuss how to choose the right repair service.
Hiring a professional for Centurion gate motor repairs
While DIY troubleshooting can be effective for simple issues, some problems may require the expertise of a professional. Hiring a reputable and experienced gate motor repair service is crucial to ensure a high-quality repair and prevent further damage.
When selecting a repair service, start by asking for recommendations from friends, family, or neighbors who have recently had gate motor repairs. Their firsthand experiences can provide valuable insights into the professionalism and reliability of different service providers.
Research the reputation of the repair services you’re considering. Check online reviews and ratings on reputable websites to get a sense of their track record. Additionally, visit their website or contact them directly to inquire about their experience with Centurion gate motors and their certifications or qualifications.
It’s important to choose a repair service that offers transparent pricing. Request a detailed quote that includes the cost of labor, parts, and any additional fees. Avoid choosing a repair service solely based on the cheapest price, as this may indicate subpar workmanship or the use of low-quality parts.
Ensure that the repair service provides a warranty for their work. A reputable repair service will stand behind their repairs and offer a warranty period to cover any potential issues that may arise after the repair.
By taking the time to research and select a reliable repair service, you can have peace of mind knowing that your Centurion gate motor is in capable hands. However, it’s important to keep in mind the cost considerations associated with gate motor repairs. We’ll discuss this in the next section.
Cost considerations for Centurion gate motor repairs
The cost of Centurion gate motor repairs can vary depending on the nature of the problem, the extent of the damage, and the repair service you choose. Understanding the cost considerations associated with gate motor repairs can help you make an informed decision.
The cost of parts is one of the primary factors that contribute to the overall repair cost. Genuine Centurion parts may be more expensive than generic alternatives, but they offer better quality and compatibility. It’s recommended to opt for genuine Centurion parts to ensure optimal performance and longevity.
Labor costs are another significant consideration. The complexity of the repair and the time required to complete it can influence the labor cost. Some repair services charge an hourly rate, while others may offer a fixed price for specific repairs. Request a detailed breakdown of the labor cost before proceeding with the repair.
Additional fees, such as call-out fees or diagnostic fees, may also be applicable. These fees cover the repair service’s travel expenses and the time spent diagnosing the problem. Clarify the existence and amount of any additional fees before agreeing to the repair.
Keep in mind that preventive maintenance can help reduce the likelihood of costly repairs in the future. By investing in regular maintenance and addressing minor issues promptly, you can potentially avoid more significant and expensive repairs down the line.
Now that we’ve covered the importance of maintenance, troubleshooting, and hiring a professional for Centurion gate motor repairs, let’s discuss some tips for preventing future gate motor issues.
Tips for preventing future CENTURION motor GATE issues
Prevention is always better than cure, and this holds true for Centurion gate motor repairs as well. By following a few simple tips, you can minimize the risk of future issues and ensure the long-term efficiency of your gate motor.
Regularly inspect your gate motor for any signs of wear, damage, or loose connections. Catching and addressing minor issues early on can prevent them from escalating into more significant problems.
Keep the gate motor clean and free from dust and debris. Regularly wipe down the motor’s exterior and clear any obstructions around it.
Ensure that the gate is properly aligned and balanced. Misaligned gates can put strain on the gate motor, leading to premature wear and potential breakdowns.
Avoid overloading the gate motor by exceeding its weight or capacity limits. Refer to the manufacturer’s guidelines for the maximum weight and size limits of the gate.
Invest in a surge protector to protect the gate motor from power surges or fluctuations. Power surges can damage the control board and other electronic components, resulting in costly repairs.
By implementing these preventive measures, you can significantly reduce the likelihood of future gate motor issues and prolong the lifespan of your Centurion gate motor.
Frequently asked questions about Centurion gate motor repairs
- Can I repair my Centurion gate motor myself?
While some minor issues can be resolved through DIY troubleshooting, more complex repairs are best left to professionals. Attempting complicated repairs without the necessary expertise can lead to further damage or safety hazards. - How often should I lubricate my Centurion gate motor?
It’s recommended to lubricate the gate motor at least twice a year. However, if your gate is exposed to harsh weather conditions or heavy usage, more frequent lubrication may be necessary. - What is the average lifespan of a Centurion gate motor?
With proper maintenance and regular repairs, a Centurion gate motor can last anywhere from 10 to 15 years or more. However, the lifespan may vary depending on factors such as usage, environmental conditions, and maintenance practices. - Can I use generic parts for Centurion gate motor repairs?
While generic parts may be cheaper, it’s recommended to use genuine Centurion parts for repairs. Genuine parts ensure compatibility and optimal performance, reducing the risk of further issues. - How can I find a reliable repair service for my Centurion gate motor?
Motsebone Garage and Gate Motors provides professional gate motor repair services around Gauteng. Contact us for affordable and professional gate motor repairs service
Conclusion: Maintaining the efficiency of your Centurion gate motor
In conclusion, keeping your Centurion motor gate running efficiently involves a combination of regular maintenance, DIY troubleshooting, and professional repairs when needed. By understanding the common issues, performing routine maintenance tasks, and following preventive measures, you can minimize the risk of future problems and extend the lifespan of your gate motor.
Remember to always prioritize safety and seek professional assistance for complex repairs or if you’re unsure about your DIY troubleshooting skills. With the knowledge and resources provided in this guide, you’ll be well-equipped to unlock efficiency and ensure smooth operations for your Centurion motor gate
CENTURION SLIDDING GATE MOTOR REPAIRS TROUBLESHOOTING GUIDE
The following is a list of standard checks to be performed prior to undertaking any of the advanced diagnostic exercises contained within this document. In the event that any fault condition is experienced, systematically go through the list to ensure that all of the
minimum site requirements are met.
1. Ensure that the following LEDs are illuminated at all times:
a. Safety Open
b. Safety Close
c. Lck/Stp
2. Check that operator is engaged.
3. Check all drive connections into the controller, i.e. battery and motor wires.
4. Check that there is a tight fit of the battery leads onto the battery terminals.
5. Check that Mains Present icon is solid.
6. Check that the origin magnet on the gate passes as closely as possible to the sensor – approximately 13mm apart.
7. Check the charge rate of the battery without the battery
connected:
a. 13.8V for D5-Evo/D5-Evo Low-Voltage
b. 27.6V for D10/D10 Turbo
8. Test battery voltage under load; should be no lower than:
a. 11V DC for D5-Evo/D5-Evo Low-Voltage
b. 22V DC for D10/D10 Turbo
Look at the date stamp on the battery and make sure that the battery is well within its usable life of three tofour years from the date on the battery.
9. Check all visible fuses.
10. Check DOSS and sensor connections.
11. Push the gate open and closed manually and check that
the gate is running freely and that there are no tight
spots in the movement of the gate.
12. Check the state of the gate wheels, examining both the
condition of the bearings and the wear on the rolling
face of the wheel.
13. Check the condition of the gate rail and ensure that it is
perfectly straight and not corrugated.
14. Check for excessive build-up of dirt on the gate rail
which might affect its free movement, and ensure that
there is no vegetation or anything else obstructing the
movement of the gate.
15. Make sure that the rack mesh is within specification
along the entire travel of the gate – the rack mustn’t
press down onto the pinion at any point.
16. Check that the gate aligns properly with its closed catch
bracket when closing.
17. Make sure that the gate is fitted with an adequate
Endstop that will stop the full force of the gate when
opening.
18. Make sure that the gate’s guide-rollers adequately
support the gate in the upright position and allow free
movement of the gate along its entire length of travel.
19. Check that the gearbox is securely mounted and properly
aligned to the movement of the gate (i.e. parallel to the
gate).
4
TYPICAL DIAGNOSTIC
MESSAGES FOUND ON THE
D-SERIES CONTROLLERS
DIAGNOSTIC MESSAGES DURING SETUP
Symptom: Unable to complete Gate Setup
Possible causes
The sensor is receiving dual pulses from the origin
magnet due to one of the following causes:
• Sensor positioned too far from the origin magnet
• Sensor and origin manget positioned at different heights
• Incorrect orientation of magnet inside enclosure
• More than one magnet on gate
• Incorrect orientation of origin magnet
• Magnetised item on rack
• Incorrect orientation of the electric motor is causing induction
• Missing pins on origin enclosure
• Faulty harness
• Faulty origin sensor
Solutions
• Ensure that the sensor is as close as possible to the origin
magnet – ideally the gap should be approximately 13mm.
Refer to Figure 1 on page 2
• Sensor and origin magnet should be positioned at the
same height
• Ensure that there is only one magnet on the gate
• Ensure that there are no items such as metal bars on the
rack that could have become magnetised
• Orientate the electrical motor so that the wires are facing
away from the controller
• Replace faulty origin sensor
• Open sensor enclosure and correct orientation of internal
magnet
5
Symptom: Unable to complete Gate Setup
Possible causes
The error indication signifies that the sensor is not
receiving a valid pulse from the gate-mounted origin
magnet, or the controller is not receiving a signal from
the sensor:
• The distance is too great between the origin sensor and
the magnet
• The magnet and sensor are mounted at different levels
• Incorrect orientation of magnet
• The gate is getting stuck at a certain point before the
magnet has passed the sensor
• Faulty origin sensor
Solutions
• Check the information screen on page 75 – it should
display the position of the magnet (left/right) when the
magnet is passing the sensor
• Ensure that the magnet and sensor are mounted at the
same level
• Ensure that there is an audible ‘click’ whenever the
magnet passes the origin sensor
• Ensure that the arrow on the magnet is facing the
operator – there should be a repelling action when the
magnet is brought near the sensor
• Move the magnet closer to the origin sensor. Refer to
Figure 1 on page 2
• Replace the origin sensor
6
Symptom: Unable to complete Gate Setup
Possible causes
• Mechanical Endstops have not been installed
• Oil in DOSS chamber
• DOSS faulty or disconnected
• Electric fence contact preventing gate from reaching fully
closed position
• Faulty electrical motor
Solutions
• Install physical Endstops in order to induce the stall
needed to stop the motor
• Ensure that the harness is connected on both the
controller and DOSS side
• Check for evidence of oil on the encoder by following the
procedure documented below: (D5-Evo/D5-Evo
Low-Voltage only)
• Remove the DOSS and carrier so that the encoder wheel
is clearly visible
• Disengage the gearbox
• Place your finger on the wheel
• Move the gate a metre or so in both directions
• Check your finger for oil
• Place an endstop approximately 100mm before the fully
closed position and perform setup procedure
• Disconnect the motor wires from the controller and place
them directly on the battery terminals to check whether
the motor runs. If not, replace the electric motor.
Symptom: Unable to complete Gate Setup
7
Solutions
• Ensure that Endstops are sturdy and do not move
• Ensure that gap between rack and pinion is approximately 3mm
• Check for missing teeth on rack
• Place an endstop approximately 100mm before the fully
closed position and perform setup procedure
DIAGNOSTIC MESSAGES DURING NORMAL
OPERATION
Symptom: Gate does not open/close.
This error indication applies to D10 and
D10 Turbo only
Audible feedback
• Five beeps periodically for 30 seconds
Possible causes
• The maximum current that should be drawn by each
D-Series controller is:
• D10: 300mA (momentarily); 200mA (continuous)
• This error indication is displayed in the event of excess
current being drawn
• Too many auxiliary components connected to 12V auxiliary
output
• One specific auxiliary device that is faulty, typically having
a short circuit
• Charging voltage significantly higher than 28V DC due to
faulty charger or controller
Possible causes
• Mechanical Endstops are not securely fitted
• Poor meshing between rack and pinion due to excessive
gap, missing teeth, etc.
• Faulty DOSS sensor
• Electric fence contact preventing gate from reaching fully
closed position
8
• Ensure that the battery charging voltage is no higher than
28V DC. Refer to Appendix A on page 71 for a description
of how to test battery and charging voltages
• Disconnect and reconnect auxiliary component one by one
in order to isolate the problem
Symptom: Gate does not open/close
Possible causes
• Beam interrupted
• Beam test inadvertently enabled
• IR beams faulty, misaligned or disconnected
• Damaged Safe Common input
Audible feedback
• One beep periodically for 30 seconds
Solutions
• Ensure that no people or objects are in the path of the
beam
• Ensure that the Safety Open and Safety Close LEDs
are illuminated – if not, the inputs can be permanently
bridged to Com – or the controller can be reset to factory
defaults
• Disable the Beam Test feature under Menu 6: IR Beams
• Ensure that the safety beams are in working order and
correctly wired
• Replace faulty controller
Solutions
9
Audible feedback
• Five beeps periodically for 30 seconds
Audible feedback
Symptom: Gate will only move for a very
short distance before termination of
operation
• Five beeps periodically for 30 seconds
Solutions
• Check connection of motor wires to controller
• Replace green motor wire connector
• Replace faulty electric motor
• Replace faulty controller
Possible causes
• Poor/intermittent motor wire connection
• Faulty electric motor
• Controller hardware problem
Symptom: Gate does not open/close
Possible causes
• DOSS physically disconnected
• Poor connection on DOSS or controller side
• Faulty harness
• Faulty DOSS
• Faulty controller
10
Solutions
• Ensure that the DOSS is clipped firmly into its carrier and
that the harness is plugged in on both the DOSS and
controller side
• Check for bad connections
• Replace DOSS harness
• Replace DOSS unit
• Replace faulty controller
Symptom: Gate does not open/close
Audible feedback
• Five beeps periodically for 30 seconds
Possible causes
• Intermittent or loose connection between motor and
controller
• The H-bridge on the controller is damaged, possibly a
blown FET
• The electric motor is faulty or has been disconnected
Solutions
• Check drive connections
• Check that the MOTOR, FUSE and DRIVE cells are all
ticked in the information screen. An ‘x’, question mark or
anything other than a tick indicate a fault. In the case of a
damaged H-bridge, the display will typically indicate the
part of the bridge that is damaged (i.e. Q1Q3, Q2Q4,
etc.). For an explanation of the information screens found
on the D-Series range of controllers, refer to Appendix B
on page 73
• Ensure that the electric motor terminals are connected to
the controller
11
• Check the function of the electric motor by referring to the
information screen described earlier, or test the motor by
connecting the motor terminals straight onto the battery.
If the motor does not run, the commutator is most
probably faulty
• In the event of a Drive Fault, the controller must be
repaired by an authorised workshop
Audible feedback
• Five beeps periodically for 30 seconds
Symptom: Gate does not open/close
Possible causes
• Intermittent or loose connection between motor and the
30A ATO motor fuse has been blown or removed
• Faulty controller
Solutions
• The MOTOR, FUSE and DRIVE cells should all be ticked in
the information screen
• For an explanation of the different screens, please refer to
Appendix B on page 73
• Check the continuity of the fuse with a multi-meter – set
the meter to ‘ohms’ or audio output
• If the fuse keeps blowing if replaced, the controller is
faulty and must be replaced
12
Symptom: Gate does not open/close, or
gate runs a short distance and stops
Audible feedback
• Four beeps periodically for ten seconds
Possible causes
• The operator is encountering a fixed obstruction
• The operator is jammed into an Endstop
• The gearbox is disengaged (D5-Evo/D5-Evo only)
• Loose drive connection (battery or motor terminal)
• Oil in DOSS chamber
• Faulty DOSS
• Sticky motor brushes
The error message will be displayed whenever
no DOSS pulses are registered while the motor is
supposed to be running
Solutions
• Ensure that the gate is running smoothly and that there is
nothing physically obstructing the gate, e.g. dirt or stones on
the rail, rack pressing down on the pinion, bad rack joints, etc.
• Connect the motor wires straight onto the battery to drive
the gate in the opposite direction and release it from the
Endstop
• Engage the gearbox by turning the thumbwheel anticlockwise (D5-Evo/D5-Evo Low-Voltage only)
• Ensure that drive connections (battery and motor wires)
are secure
• Check for evidence of oil on the encoder by following the
procedure below: (D5-Evo/D5-Evo Low-Voltage only)
• Remove the DOSS and carrier so that the encoder wheel
is clearly visible
• Disengage the gearbox
• Place your finger on the wheel
• Move the gate a metre or so in both directions
• Check your finger for oil
• Replace faulty DOSS
• Arrange service with an authorised workshop
13
Audible feedback
Symptom 1: Gate does not close from the
fully open position
Symptom 2: Gate does not open from the
fully closed position
• Five beeps periodically for 30 seconds
Possible causes
• The Beam Test feature has been inadvertently activated
• The safety beam transmitter has been wired to normal
common – as opposed to safe common – with the Beam
Test enabled
• The incorrect operating profile for the region has been
selected. The UL325 and CE profiles will always perform
a beam test before allowing the gate to run
• Beams not aligned
• Damaged SAF COM input
• Incorrect beam wiring
• Faulty closing/opening beams
Solutions
• Ensure that the beams are correctly wired and that the
connections are secure. Refer to the wiring diagrams on
pages 80 and 81
• If not required, Disable the Beam Test feature under
Menu 6: IR Beams
• Connect the transmitter negative to Safety Com
• Ensure that you select the correct profile for the region the
operator is being installed in, e.g. ZA (Menu 10: General
Settings)
• Check beam alignment
• Perform a Factory Reset operation, bridge Safety Open to
Com or refit the beams if they have been disconnected
• Replace the beams
• Replace faulty controller
14
Audible feedback
Symptom: Gate does not open/close,
or gate runs a short distance and stops
• Four beeps periodically for ten seconds
Possible causes
• The operator is encountering an obstruction and has
reached the pre-set number of allowable collisions
• Gate rack resting on pinion
• Seized gate wheels
• The controller collision force is set too sensitively
• Number of allowable collisions set to a low value, e.g. 1
• Damaged encoder wheel
• Tight gearbox
• Oil on DOSS
• Faulty DOSS harness
• Loose drive connections
• Gearbox not fully engaged
• Faulty DOSS sensor
• Faulty electric motor
Solutions
• Ensure that the gate is running smoothly and that there is
nothing physically obstructing the gate, e.g. dirt or stones
on the rail, rack pressing down on pinion, bad rack joints,
etc.
• There should be a 2 – 3mm gap between the rack and the
pinion
• Increase the Collision Force (Menu 2: Safety)
• Increase maximum collisions value to a higher number,
typically 4
• Check for evidence of oil on the encoder by following the
procedure below: (D5-Evo/D5-Evo Low-Voltage only)
15
Symptom: Gate does not open/close
• Remove the DOSS and carrier so that the encoder
wheel is clearly visible
• Disengage the gearbox
• Place your finger on the wheel
• Move the gate a metre or so in both directions
• Check your finger for oil
• Replace faulty DOSS harness
• Check battery and motor terminal connections
• Ensure that operator is fully engaged
• Replace faulty DOSS sensor
• Replace faulty electric motor
• Have the operator serviced by an authorised workshop
Audible feedback
• Three short beeps for five seconds
Possible cause
• The End-of-Travel limits have not been established
Solution
• Set the gate travel limits by accessing the Setting Limits
menu (Menu 1: Setting Limits) and following the onscreen
prompts
16
Symptom: Gate does not open/close
Audible feedback
• Three short beeps periodically for 30 seconds
Possible causes
• Poor connection between battery and controller
• The battery voltage is low
• The battery is faulty or disconnected
• Faulty controller
Solutions
• Ensure that the battery terminals are properly connected
on both the controller and battery side
• Measure the battery voltage – it should be no lower than
11V DC for the D5-Evo or 22V DC for the D10/D10 Turbo
when placed under load. Refer to Appendix A on page
71 for an explanation of how to accurately test battery
voltage
• Check for corrosive build-up around the battery terminals.
If there is corrosion, replace both the battery and
terminals
• Replace the battery
• Ensure that the ‘Mains Present’ icon is solid
• Measure the charger’s output voltage. It should be about
14V for the D5-Evo/D5 Evo Low-Voltage and 27V for the
D10/D10 Turbo
• Replace faulty controller
17
GENERAL INFORMATION SCREENS
Symptom: None
Audible feedback
• 4KHz tone for 30 seconds
Possible causes
• The IR Beams have been interrupted for the pre-set period
of time with the Ambush Alarm feature enabled
• Inadvertent activation of the Ambush Alarm feature
Solutions
• Clear any obstruction from the path of the beams
• If the lenses are unobstructed, check the wiring between
the beams and the controller (refer to the wiring
diagrams on page 80 and 81), as well as between the IRB
transmitter and receiver
• Ensure that the beams are properly aligned
• If not required, disable the Ambush Alarm feature in
Menu 6: IR Beams
Symptom: None
Audible feedback
• 4KHz tone for 30 seconds
18
Possible causes
• The IR Beams have been interrupted with the gate in the
fully closed position
• Inadvertent activation of the Break-in Alarm feature
Solutions
• Clear any obstructions from the path of the beams
• If the lenses are unobstructed, check the wiring between
the beams and the controller, as well as between the IRB
receiver and transmitter
• Ensure that the beams are properly aligned
• If not required, disable the Break-in Alarm feature in
Menu 6: IR Beams
Audible feedback
• One beep periodically for 30 seconds
Possible cause
• The Holiday Lockout feature has been enabled
Solutions
• Ensure that the green Lck/Stp LED is illuminated
• Press the transmitter button or switching device that
invoked Holiday Lockout Mode
• Bridge the Lck input to Com or reset the controller to
factory defaults (Menu: General Settings)
• Check for any Auto-activations pertaining to Holiday
Lockout. Refer to the Time-barring and Auto-activation
matrix, a depiction of which is given in Appendix B, page 73
Symptom: Gate does not open from fully
closed position
19
D2 Turbo/D2 Turbo Low-Voltage
The D2 Turbo/D2 Turbo Low-Voltage sliding gate
operators for domestic gates are renowned for their
supremely easy setup, incredibly user-friendly interface and
click-together modular design.
Like all Centurion operators, the D2 Turbo/D2 Turbo
Low-Voltage will give feedback should it encounter any
errors in its operation, using a combination of the Status LED
and the onboard buzzer to provide users with the
information necessary to perform diagnostic exercises.
SLIDING
centurion motor gates Services Areas
- Vorna Valley
- Noordwyk
- Country View
- Dainfern
- Fourways
- Halfway House
- Riverside View
- Blue Hils
- Clayville
- Glenferness
- Barbeque Downs
- Centurion
- Sandton
- Lonehill
- Pretoria
- Jukskei View
- Sagewood
- Kyalami
- Randjespark
- Riversands
- Waterfall
- Vorna Valley
- Beaulieu
- Crowthorne AH
- Olifantsfontein
- Hillaway
- Kempton Park
- Edenvale
- Germiston
- Johannesburg
- Summerset
- Steyn City
- Savannah Hills Estate
- Halfway Gardens
- Allendale
- Austin View
- President Park
- Country View
- Glen Austin AH
- Carlswald
- Crescent Wood Country Estate
- Bedfordview
- Randburg
- Benoni
- Roodepoort