Centurion gate motor does not open or close

One beep periodically for 30 seconds

Message: Beams active / safety beams active

Possible cause

• Beam interrupted
• Beam test inadvertently enabled
• IR beams faulty, misaligned or disconnected
• Damaged Safe Common input

Solution

• Ensure that no people or objects are in the path of the
beam
• Ensure that the Safety Open and Safety Close LEDs
are illuminated – if not, the inputs can be permanently
bridged to Com – or the controller can be reset to factory
defaults
• Disable the Beam Test feature under Menu 6: IR Beams
• Ensure that the safety beams are in working order and
correctly wired
• Replace faulty controller

Five beeps periodically for 30 seconds 

Message: Current sensor fault reading too high/low

Possible cause

• Poor/intermittent motor wire connection
• Faulty electric motor
• Controller hardware problem

Solutions

• Ensure that the DOSS is clipped firmly into its carrier and
that the harness is plugged in on both the DOSS and
controller side
• Check for bad connections
• Replace DOSS harness
• Replace DOSS unit
• Replace faulty controller

Five beeps periodically for 30 seconds

Message: DOSS FAULT / DOSS FAULT-DISCONNECTED

Causes

• DOSS physically disconnected
• Poor connection on DOSS or controller side
• Faulty harness
• Faulty DOSS
• Faulty controller

Solution

• Ensure that the DOSS is clipped firmly into its carrier and
that the harness is plugged in on both the DOSS and
controller side
• Check for bad connections
• Replace DOSS harness
• Replace DOSS unit
• Replace faulty controller